Intraoral Scanner Aoralscan Elite
€17.500,00 excl. VAT
SHINING 3D offer
Added value+ €1.800 prosthetic work credit
„Choose your own lab – IMMT pays for work up to €1.800.“
How the credit worksPrice incl. VAT · VAT invoice with every order
DPD / UPS courier delivery · usually 2–7 business days
EU companies with a valid VAT number buy without VAT – enter your VAT number at checkout.
Need an offer or want to see it in action?
Aoralscan Elite – the world's first device to combine intraoral scanning (IOS) and photogrammetry (IPG) in a single unit. It substantially increases accuracy and efficiency in implantology and simplifies the clinician's daily workflow. Key benefits:• 2-in-1 system (IOS + IPG): digital scanning...
Description- Consultations
- Help choosing the configuration and materials
- Delivery
- In Lithuania, the Baltic states and worldwide
Questions about this product?
Our product specialist will help you choose the right configuration.
Description
Aoralscan Elite – the world's first device to combine intraoral scanning (IOS) and photogrammetry (IPG) in a single unit. It substantially increases accuracy and efficiency in implantology and simplifies the clinician's daily workflow.
Key benefits:
• 2-in-1 system (IOS + IPG): digital scanning and photogrammetry combined directly – particularly effective in edentulous cases, especially for All-on-X restorations.
• Outstanding accuracy: scanning accuracy up to 5 µm for top-quality results.
• Faster, simpler work: shorter procedures and a smoother, more consistent clinic-to-lab workflow.
• Versatile use: all standard IOS indications plus implant photogrammetry in one modern device.
Advantages
• Take digital impressions of edentulous patients too – for All-on-X restorations.
• Thanks to its dual functionality, Aoralscan Elite is extremely versatile: standard implant cases, orthodontic treatment planning, smile aesthetics and more, as well as advanced treatment of edentulous patients.
• Compact and lightweight – just 124 g. The ergonomic body sits comfortably in the hand, making work easier and more pleasant.
• Includes advanced software with model creation and 3D print preparation features.
• Works as a standard intraoral scanner (IOS) for capturing dental images; scans teeth and oral soft tissues in detail.
• Works as a photogrammetry system (IPG) – accurately records implant positions in edentulous patients.
• Tips in three sizes – a wide IPG tip for edentulous patients, a standard tip for adults and a mini tip for children
IPG (intraoral photogrammetry)
An innovative technology developed by SHINING 3D.
A technology where clinical dental experience meets scientific progress.
A technology that combines intraoral scanning and photogrammetry in a single device.
It is the first technology of its kind in digital dentistry.
IPG
Photogrammetry technology for high-quality scanning of edentulous patients in All-on-X implant cases.
IOS
Intraoral scanning technology for all other dental needs.
Seamless scanning of edentulous patients
124 g – ultra-light and ergonomic
Weighing just 124 g, Aoralscan Elite is the lightest intraoral scanner. It sits perfectly in the hand and offers outstanding working comfort.
Applications
The Aoralscan Elite intraoral scanner can be used for a wide range of clinical indications, covering restorative dentistry, implantology and orthodontics. Its key advantage, however, is high-quality scanning of edentulous cases. Whether for single-visit restorations or integrated treatment delivered jointly by the clinic and the dental lab, Aoralscan Elite always provides a state-of-the-art user experience.
Technical data
- Single-frame field of view
- – IPG tip
19 × 14 mm
- – Standard tip
16 × 12 mm
- – Mini tip
12 × 9 mm
- Scanning depth
22 mm from the tip exit surface
- Scanning principle
non-contact structured light scanner + intraoral photogrammetry
- Dimensions (L × W × H)
245 × 30 × 26 mm
- Weight
124 g (without cables)
- Output format
STL, OBJ, PLY
- Connection port
USB Type-C
- Power supply
5 V DC / 3 A
- Recommended Mac configuration
- Processor
at least M2 (8-core CPU, 10-core GPU); recommended: M1 Pro (8C CPU / 14C GPU), M2 Pro (10C / 16C GPU), M1 Max (10C CPU / 24 or 32C GPU), M3 (8C CPU / 10C GPU), M4 (10C CPU / 10C GPU)
- RAM
16 GB or more
- Storage
SSD, 1 TB recommended
- System
macOS Ventura 13 or later
- Interface
at least one USB-C (Type-C) port
- Recommended PC configuration
- CPU
Intel Core i7-8700 or newer
- RAM
32 GB recommended
- Storage
SSD 256 GB or more
- Graphics card (GPU)
NVIDIA® RTX 2060 6 GB or newer
- Operating system
Windows 10 Professional (64-bit) or later
- Display resolution
1920 × 1080, 60 Hz or higher
- I/O ports
USB Type-C
Frequently asked questions
What makes the Aoralscan Elite special?
It is the first device to combine intraoral scanning (IOS) and photogrammetry (IPG) in a single unit – especially effective in All-on-X cases for edentulous patients. Scanning accuracy up to 5 μm.
How much does the scanner weigh?
124 g without cables – the lightest intraoral scanner in its class; dimensions 245 × 30 × 26 mm, connects via USB Type-C.
Does it work with Mac computers?
Yes. Recommended: at least Apple M2 (8-core CPU / 10-core GPU), 16 GB RAM, SSD, macOS Ventura 13 or later and a USB-C port. For PC – Intel Core i7-8700 or newer.
Can the tips be sterilized?